Oversetter...
F47
System bus 1 timeout
SEW Eurodrive · MOVITRAC 07B System
Hva betyr F47 ?
A stop without inhibit occurs due to a communication fault via system bus 1. This can be related to the bus connection, parameter P808, the voltage supply of the FSE24B module, or EtherCAT communication issues with the connected FSE24B.
Vanlige årsaker
- Fault during communication via system bus
- Incorrect setting of parameter P808
- Voltage supply issue of FSE24B module
- EtherCAT communication problem with connected FSE24B
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Check system bus connection for integrity, including cables and connectors
- 2
Check the value of parameter P808 for correct configuration
- 3
Check voltage supply of the FSE24B module
- 4
Check EtherCAT communication with the connected FSE24B for data exchange
Verifisert teknisk data. Sist oppdatert: March 2026
Relaterte feilkoder
Kilde: SEW Eurodrive MOVITRAC 07B System