61
Speed Error
Vacon · NX All-in-One Application
Hva betyr 61 ?
The measured motor speed deviates significantly from the commanded speed reference. For Permanent Magnet Synchronous (PMS) motors, this can also indicate that the motor has exceeded its pull-out torque, leading to loss of synchronization.
Vanlige årsaker
- Motor speed deviates significantly from the setpoint (e.g., P1-01).
- Inadequate torque to maintain speed under load.
- Encoder feedback issues (e.g., lost pulses, incorrect resolution).
- Tuning parameters (e.g., P2-01 to P2-06) not optimized.
- Mechanical system exhibiting resonance or instability.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Inspect the encoder connection and wiring to ensure proper speed feedback to the drive.
- 2
Verify motor loading and ensure the motor is not operating beyond its pull-out torque capacity, especially for PMS motors.