Overcurrent
Omron · 3G3EV Inverter
What does %c mean?
This protective fault indicates that the Inverter output current instantaneously exceeded 250% of the rated amperage. Common causes include a short circuit or ground fault on the output side, excessive load inertia, acceleration/deceleration times set too short, use of a special motor, starting the motor during free running, or operating a magnetic contactor on the output side. Unresolved overcurrent can severely damage the inverter's output stage or connected motor.
Additional Steps
Steps 1–2 are listed in Priority Fix.
- 3
Avoid starting the motor while it is still free-running. Ensure the magnetic contactor on the output side of the inverter is not opened or closed during operation.
- 4
If a special motor is used, verify its compatibility and settings with the inverter.
- 5
After addressing the cause, perform a fault reset on the system.