37810000 hex
Process Data Object Setting Missing
Omron · NJ/NY-series NC Integrated Controller
What does 37810000 hex mean?
A minor fault indicating incorrect Process Data Object (PDO) mapping within the CNC Function Module for a CNC coordinate system. This fault is detected at instruction execution. While the user program continues, operations for the relevant CNC coordinate systems are not possible.
Common Causes
- Required Process Data Objects (PDOs) for the CNC instruction are not correctly mapped.
- A CNC instruction was executed for a device that lacks the necessary object support for that instruction.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Verify and correct the PDO mapping for the specific CNC instruction in use, ensuring all required PDOs are configured and mapped.
- 2
Consult the device manual to confirm whether the device supports the specific CNC instruction being executed.
- 3
Modify the CNC program to ensure that only supported instructions are executed on the target device.
Verified technical data. Last updated: March 2026
Related Faults
Source: Omron NJ/NY-series NC Integrated Controller