901
PCU IST FAULT
Otis · DSD 412 DC Elevator Drive
What does 901 mean?
Current flow in excess of 300% of the rated armature current is detected within the armature circuit. This indicates a severe overload, a fault in the motor, or a measurement error.
Common Causes
- Ground fault or an intermittent connection within the motor armature circuit.
- Malfunction or failure of the current measuring module.
- Suboptimal tuning or configuration of the current regulator.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Inspect the motor armature circuit for any ground faults or intermittent connections.
- 2
Test the current measuring module for accurate readings and replace if faulty.
- 3
Review and adjust the current regulator tuning parameters.