917

REVERSE ARMATURE POLARITY

Otis · DSD 412 Elevator System

What does 917 mean?

The polarity of the Armature Voltage Feedback wires is reversed or the wires are missing. This fault shows up during the F998 PCU Diagnostics Test and can cause F909 faults or very poor drive/ride performance if not corrected. This fault requires a DSD power down.

Common Causes

  • Reversed or missing Armature Voltage Feedback wires.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check connections on A1TB5-1 and A1TB5-2 of the Armature Interface PCB, A2, for correct polarity and presence.

  2. 2

    Perform the F998 PCU Diagnostics Test to verify the correction.

Browse all codes in this manual (57)
Verified technical data. Last updated: March 2026

Related Faults

Source: Otis DSD 412 Elevator System