923
LOAD CURRENT SETTING FAULT
Otis · DSD 412 Elevator System
What does 923 mean?
This fault is declared if a number entered for Rated Armature Current, #3, is outside the acceptable range of 0.125 to 2.0 times the bridge current rating. The bridge current rating is determined by the bridge sense resistor on the Cube ID PCB, located on the Armature Interface PCB. This fault requires a DSD power down.
Common Causes
- Rated Armature Current parameter #3 set outside the acceptable range relative to the bridge current rating.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Enter a valid number for Rated Armature Current, #3, within 0.125 to 2.0 times the bridge current rating (determined by the Cube ID PCB sense resistor).
Verified technical data. Last updated: March 2026