933
Motor armature current does not increase to near test amps within 6 seconds.
Otis · DSD 412 Elevator System
What does 933 mean?
This fault indicates that the motor armature current failed to reach near the specified test amperes within 6 seconds. This may occur during Self-Tune (Function #997) or Self-Diagnostic (Function #998).
Common Causes
- Faulty motor armature circuit, possibly an open circuit.
- Open SCR or missing SCR gating pulses.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Check the motor armature circuit wiring for any open circuits.
- 2
Inspect the motor itself for any internal open circuits.
- 3
Perform Self-Diagnostics (Function #998) to verify the status of SCRs and their gating.
Verified technical data. Last updated: March 2026
Related Faults
Source: Otis DSD 412 Elevator System