933

Motor armature current does not increase to near test amps within 6 seconds.

Otis · DSD 412 Elevator System

What does 933 mean?

This fault indicates that the motor armature current failed to reach near the specified test amperes within 6 seconds. This may occur during Self-Tune (Function #997) or Self-Diagnostic (Function #998).

Common Causes

  • Faulty motor armature circuit, possibly an open circuit.
  • Open SCR or missing SCR gating pulses.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the motor armature circuit wiring for any open circuits.

  2. 2

    Inspect the motor itself for any internal open circuits.

  3. 3

    Perform Self-Diagnostics (Function #998) to verify the status of SCRs and their gating.

Browse all codes in this manual (57)
Verified technical data. Last updated: March 2026

Related Faults