940

Field Current Feedback A/D Saturated

Otis · DSD 412 Elevator System

What does 940 mean?

This fault occurs when the Field Analog-to-Digital (A/D) converter reading remains saturated for more than 15 seconds, indicating an issue with the field current feedback circuit.

Common Causes

  • Component problem with the Field Interface Board.
  • Problem with the Ribbon Cable (J33) connecting components.
  • Component problem with the Main Control Board.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Replace the Field Interface Board.

  2. 2

    Replace the Ribbon Cable (J33).

  3. 3

    If the fault is still present after these steps, replace the Main Control Board.

Browse all codes in this manual (57)
Verified technical data. Last updated: March 2026

Related Faults

Source: Otis DSD 412 Elevator System