M020

Total Input Power Exceeded

Schindler · Altivar 212 Variable Frequency Drive

What does M020 mean?

This fault occurs when the accumulated input power value, typically measured in kWh, exceeds the maximum displayable value of 999.999 kWh, indicating a data overflow.

Common Causes

  • Accumulated input power value has exceeded 999.999 kWh.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Clear the accumulated input power value using logic input function 51 (Reset kWh).

  2. 2

    Alternatively, clear the accumulated input power value by setting parameter F748 ([Power cons. memo]) to 0 (Disable) and then cycling power to the drive.