OCL

Short Circuit Motor Cable at Start

Schindler · Altivar 212 Variable Frequency Drive

What does OCL mean?

This fault indicates a phase-to-phase output short circuit or a low motor impedance detected in the motor or its wiring during startup by the Altivar 212 drive.

Common Causes

  • Phase-to-phase output short circuit in motor or cables.
  • Motor impedance is too low.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Use a 1000 V testing tool (megger) to check the motor windings for phase-to-phase insulation resistance.

  2. 2

    Use a 1000 V testing tool (megger) to check the motor cables for phase-to-phase insulation resistance.