OL2
Motor Overload
Schindler · Altivar 212 Variable Frequency Drive
What does OL2 mean?
This fault indicates a motor overload condition, potentially caused by incorrect motor control settings, a jammed motor, continuous low-speed operation, or excessive load from the Altivar 212 drive.
Common Causes
- Incorrect setting of [Mot cont. mode sel.] (Pt).
- The motor is jammed or mechanically binding.
- Continuous low-speed operation is performed.
- Excessive mechanical load is applied to the motor.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Select the correct setting for parameter [Mot cont. mode sel.] (Pt).
- 2
Check the mechanical load for any binding or obstructions.
- 3
Adjust parameter OLM ([Motor overload prot]) to the overload level that the motor can withstand during low speed operation.
Verified technical data. Last updated: March 2026
Related Faults
Source: Schindler Altivar 212 Variable Frequency Drive