Ot
Overtorque
Schindler · Altivar 212 Variable Frequency Drive
What does Ot mean?
This fault occurs when the calculated motor torque reaches or exceeds the level set by parameter F616 ([Overtorque level]), indicating that the motor is operating under excessive load and could be damaged.
Common Causes
- Calculated motor torque has reached the level set by parameter F616.
- Excessive mechanical load on the motor.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Adjust the settings of parameters F615 ([Overtorque det.]) and F616 ([Overtorque level]) as needed.
- 2
Verify the machine operation to identify any mechanical binding or obstructions causing high torque.
Verified technical data. Last updated: March 2026