A-17
Alarm Button (Remote Display)
Schneider Electric · Altivar 312 Variable Frequency Drive
What does A-17 mean?
This alarm is displayed on the remote terminal when a button has been held down for an extended period (more than 10 seconds), or if the keypad is disconnected. It suggests a physical issue with the terminal's buttons, or a faulty connection of the keypad itself, which can prevent proper input.
Complete Troubleshooting Guide
- 1
Inspect all buttons on the remote display terminal for any that may be physically stuck in the pressed position.
- 2
Verify the secure connection of the keypad module to the remote display terminal.
- 3
Clean the keypad surface and buttons to ensure no foreign material is causing interference.
- 4
If the issue persists after checking buttons and connections, replace the remote display terminal.