FCF1

Output Contactor Stuck Closed

Schneider Electric · Altivar Machine ATV320 Variable Speed Drive

What does FCF1 mean?

Indicates that the output contactor is detected as stuck in the closed position when it should be open. This is a critical safety fault, as power may still be applied to the motor when it should be disconnected, leading to uncontrolled startup or dangerous conditions.

Complete Troubleshooting Guide

  1. 1

    Immediately verify that all power to the drive and motor is disconnected for safety.

  2. 2

    Inspect the output contactor for welded contacts, pitting, or mechanical sticking.

  3. 3

    Manually actuate the contactor to check for free movement and reliable opening.

  4. 4

    Measure continuity across the contactor terminals to confirm its open state when de-energized.

  5. 5

    Replace the faulty output contactor if it fails to open reliably.