Internal Fault
Schneider Electric · Altivar Machine ATV340 Programming
What does -InF mean?
This fault signifies a general internal malfunction within the drive controller, possibly related to internal circuitry or connections. Electromagnetic interference (EMI) can sometimes induce such faults, or it could be a hardware failure. Continued operation with an internal fault is not possible and requires immediate attention to prevent further damage or unexpected behavior.
Complete Troubleshooting Guide
- 1
Identify and mitigate potential sources of electromagnetic interference (EMI) near the drive controller and its control wiring, ensuring proper grounding and shielding.
- 2
Verify that any connected accessories, such as the start/stop potentiometer kit (VW3A28100), were not connected or disconnected while the drive was powered. Power cycle the drive after verification.
- 3
If the fault persists after checking EMI and accessory connections, the drive controller likely has a permanent internal hardware failure and needs replacement.