82
Output Phases Interrupted
SEW Eurodrive · MOVIMOT® MM..D with AC Motor DT/DV / Operating Instruc
What does 82 mean?
This fault indicates that two or all output phases between the MOVIMOT inverter and the motor are interrupted or open. This prevents current delivery to the motor windings, leading to motor non-operation and potential inverter damage if operated under such conditions.
Common Causes
- Two or all output phases are interrupted.
- Rated motor power is too small in relation to the rated inverter power.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Check the connection between the MOVIMOT inverter and the motor for interrupted output phases.
- 2
Verify that the rated motor power is appropriately matched with the rated inverter power.
- 3
Reset the fault by switching off and then switching on the DC 24V supply voltage.
- 4
Reset the error via the error reset function.
Verified technical data. Last updated: March 2026
Related Faults
Source: MOVIMOT® MM..D with AC Motor DT/DV / Operating Instruc