01
Overcurrent in Output Stage
SEW Eurodrive · [PDF] MOVIMOT® MM..D with AC Motor DT/DV / Operating Instruc
What does 01 mean?
This fault indicates an excessive current flow detected in the inverter's output stage, leading to a motor stop. This typically signals a short circuit condition on the inverter's output or within the motor winding, which can damage the inverter's power components.
Common Causes
- Short circuit on inverter output.
- Short circuit in the connection between inverter output and motor.
- Short circuit within the motor winding.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Check the connection between the inverter output and the motor for short circuits.
- 2
Check the motor winding for short circuits.
- 3
Reset the fault by switching off and then switching on the DC 24V supply voltage.
- 4
Reset the error via the error reset function.
Verified technical data. Last updated: March 2026
Related Faults
Source: [PDF] MOVIMOT® MM..D with AC Motor DT/DV / Operating Instruc