08
n-Monitoring
SEW Eurodrive · MOVIDRIVE compact MCF/MCV/MCS4_A
What does 08 mean?
Immediate switch-off because the speed controller or current controller is operating at its setting limit. This can be due to mechanical overload, a phase failure in the power supply or motor, an incorrectly connected encoder, or exceeding the maximum speed (nmax) during torque control.
Additional Steps
Steps 1–2 are listed in Priority Fix.
- 3
Check the encoder connection; if necessary, swap A/A and B/B signal pairs to correct direction.
- 4
Verify the encoder voltage supply is stable and within specifications.
- 5
Check the current limitation settings (e.g., P303 for maximum current).
- 6
Extend acceleration/deceleration ramps if current limits are being hit.
Source: SEW Eurodrive MOVIDRIVE compact MCF/MCV/MCS4_A