82

Open output Immediate disconnection

SEW Eurodrive · MOVIDRIVE compact System

What does 82 mean?

This fault occurs in 'VFC hoist' operating mode when two or all output phases to the motor are interrupted. It can also indicate a significant mismatch where the rated motor power is too small relative to the inverter's power. The inverter detects an open circuit condition on its output, leading to immediate disconnection.

Complete Troubleshooting Guide

  1. 1

    Thoroughly check all connections between the inverter and the motor for continuity across all phases, ensuring no breaks or loose connections.

  2. 2

    Verify the motor's winding resistance to ensure no internal phase interruptions within the motor itself.

  3. 3

    Confirm that the rated motor power is correctly matched to the inverter's power rating, and update startup data if adjustments are made.

  4. 4

    Perform a new startup procedure after checking connections and power ratings to re-evaluate the system.