01

Overcurrent in output stage

SEW Eurodrive · MOVIMOT MM..D With AC Motor DRS

What does 01 mean?

An overcurrent condition has been detected in the inverter's output stage, often due to a short circuit. This can occur either within the inverter output itself, the connecting cable to the motor, or the motor windings.

Common Causes

  • Short circuit on inverter output
  • Short circuit in the connection between inverter output and motor
  • Short circuit in the motor winding

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the connection between the inverter output and the motor for short circuits

  2. 2

    Check the motor winding for short circuits

  3. 3

    Reset the error by switching off the DC 24 V supply voltage

  4. 4

    Reset the error via the control system or dedicated reset function

Browse all codes in this manual (16)
Verified technical data. Last updated: March 2026

Related Faults

Source: SEW Eurodrive MOVIMOT MM..D With AC Motor DRS