F82

Open output

SEW Eurodrive · MOVITRAC 07B System

What does F82 mean?

An immediate switch-off with inhibit occurs only in 'VFC hoist' operating mode. This indicates that two or all output phases are interrupted, or the rated motor power is too small relative to the inverter's rated power, preventing proper motor operation.

Common Causes

  • Two or all output phases interrupted (VFC hoist mode)
  • Rated motor power too small in relation to rated inverter power

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the connection between the inverter and motor for interrupted phases or loose terminals

  2. 2

    Check startup data and perform a new startup procedure if necessary, ensuring motor parameters are correctly set