F07860

External fault 1

Siemens · DCM

What does F07860 mean?

An external monitoring device or system has triggered the "external fault 1" input signal to the drive. This indicates a critical condition detected by equipment outside of the drive's internal monitoring, requiring investigation of the connected external safety chain or process. Ignoring this fault can lead to equipment damage or unsafe operating conditions.

Complete Troubleshooting Guide

  1. 1

    Identify the specific external device or system connected to the "External fault 1" input (e.g., safety relay, thermal overload, pressure switch).

  2. 2

    Inspect the status of that external device and its associated process to determine why it triggered the fault.

  3. 3

    Check the wiring and configuration of the BICO signal for "External fault 1" (parameter p2106).