Maximum frequency exceeded
Siemens · SINAMICS G120 Variable Speed Drive
What does F01613 mean?
The drive has detected that the motor's operating frequency has exceeded the configured maximum limit, as monitored by one or both internal processors. This can occur due to an application anomaly, incorrect parameterization of speed limits, or an issue with the safety monitoring system, potentially leading to overspeed and mechanical damage.
Complete Troubleshooting Guide
- 1
Review the application's speed commands and control logic to ensure the drive is not commanded to exceed its limits.
- 2
Adjust the safety threshold parameters p9691 and/or p9891 if the current limit is too restrictive for the application, ensuring it remains within safe operating bounds.
- 3
Consult the remedies for F1614 if that fault is also present or related, as indicated by the manual.