F07082

Macro: Execution not possible

Siemens · SINAMICS G120C Variable Speed Drive

What does F07082 mean?

This fault occurs when a macro cannot be executed due to various configuration or data errors. The fault value (r0949, hexadecimal) provides detailed supplementary information, indicating issues such as an invalid file for the trigger parameter, incorrect data types within the macro (e.g., index, number, or bit not U16), undefined error levels or modes, or attempts to write to parameters that are read-only or not available via macro. Such issues prevent automated configuration or specific functions from running.

Complete Troubleshooting Guide

  1. 1

    Interpret the fault value (r0949) to pinpoint the specific cause (e.g., invalid file, data type error, or parameter write restriction).

  2. 2

    Verify the macro definition for correct parameter numbers, data types, and access permissions.

  3. 3

    Ensure all referenced files and parameters within the macro are valid and accessible.