A35411

TM150 Temperature Alarm Channel 5

Siemens · SINAMICS S120/S150 List

What does A35411 mean?

This alarm is initiated when the actual temperature (r4105[5]) for channel 5 on Terminal Module 150 (TM150) exceeds its configured alarm threshold (p4102[10]). A timer (p4103[5]) is also started. The alarm will clear once the temperature falls below the threshold, factoring in the defined hysteresis (p4118[5]).

Additional Steps

Steps 1–2 are listed in Priority Fix.

  1. 3

    Check for any immediate causes of temperature increase for the affected component, such as temporary overloads or environmental factors.

  2. 4

    Verify the temperature sensor operation and connection for channel 5.

  3. 5

    Review the alarm threshold setting (p4102[10]) and hysteresis (p4118[5]) to ensure they are appropriate for the application.

Source: Siemens SINAMICS S120/S150 List