206105

Infeed: Line supply undervoltage alarm

Siemens · SINUMERIK 828D CNC Control

What does 206105 mean?

An alarm indicating that the filtered, steady-state value of the line supply voltage has dropped below the alarm threshold set by p0282. This is a warning condition, not a shutdown, meaning there is no immediate reaction. The alarm value (r2124) shows the current line supply voltage.

Complete Troubleshooting Guide

  1. 1

    Check the incoming line supply for any transient voltage sags or sustained undervoltage conditions.

  2. 2

    Verify that the line supply voltage parameter (p0210) is correctly configured to match the connected power supply.

  3. 3

    Review and adjust the line supply undervoltage alarm threshold (p0282) if the current setting is too sensitive or does not align with operational requirements.