207082

Macro execution not possible

Siemens · SINUMERIK 828D CNC Control

What does 207082 mean?

A macro program could not be executed due to various underlying causes. The fault value (r0949, hexadecimal) provides detailed information, including the preliminary parameter number, supplementary information, and the specific fault cause. This can range from invalid files, incorrect data types, or unauthorized parameter writes, preventing the macro from completing its intended function.

Complete Troubleshooting Guide

  1. 1

    Interpret the hexadecimal fault value (r0949) to determine the specific fault cause (aa), supplementary information (bb), and preliminary parameter number (cccc).

  2. 2

    Verify the validity and correctness of the macro file being called, especially its compatibility with the specified trigger parameters (e.g., parameters 15, 700, 1000, 1500).

  3. 3

    Check all TAG data types, error levels, and modes within the macro for correct definition and ensure no invalid strings are used for parameter values.

  4. 4

    Confirm that the drive object type is correctly specified and that the target device for the macro operation can be found.

  5. 5

    Ensure that the parameter being written to by the macro is permitted to be modified via this method, as some parameters may be write-protected.