22320

PUTFTOCF command could not be transferred

Siemens · SINUMERIK 828D CNC Control

What does 22320 mean?

This alarm indicates that the cyclic transfer of the PUTFTOCF data block (fine tool compensation) failed because the transfer area is already occupied. This commonly occurs if another channel is simultaneously attempting to transfer a data block, creating a resource conflict. If left unaddressed, this prevents fine tool compensation from being applied, potentially leading to inaccuracies in machining and affecting product quality.

Complete Troubleshooting Guide

  1. 1

    Check the part program for the active channel and other channels to identify if multiple data blocks are being transferred concurrently.

  2. 2

    Optimize part program sequencing to avoid simultaneous PUTFTOCF transfers from different channels.

  3. 3

    Clear the alarm with the RESET key and restart the part program.