SI MM: STOP A initiated
Siemens · SINUMERIK 828D CNC Control
What does 230600 mean?
This fault signifies that the drive-based Safety Integrated (SI) function in the Motor Module (MM) has detected a critical anomaly, initiating a STOP A (pulse suppression via the safety shutdown path of the Motor Module). This can result from an unsuccessful forced checking procedure of the safety path, an internal software error (fault value 1020), or a response to a monitoring channel defect (F30611). This safety-critical fault immediately halts motor operation to prevent hazardous conditions, requiring immediate attention to restore safe functionality.
Complete Troubleshooting Guide
- 1
Select and then de-select Safe Torque Off (STO) to attempt resetting the safety circuit.
- 2
If fault value is 1020, perform a POWER ON (power off/on) for all components, consider upgrading the Motor Module software, or replace the Motor Module.
- 3
If fault value is 9999, perform diagnostics for fault F30611, which indicates a defect in a monitoring channel.
- 4
Replace the involved Motor Module if the issue persists after initial troubleshooting steps.