F07016

Temperature sensor fault

Siemens · SINUMERIK 828D CNC Control

What does F07016 mean?

A temperature sensor fault has been detected. This fault is output if alarm A07015 (temperature sensor fault) persists beyond the timer set in p0607, after at least 1 second. The fault value (r0949) indicates the number of the sensor channel that triggered the message.

Complete Troubleshooting Guide

  1. 1

    Check that the temperature sensor is connected correctly to the drive, ensuring all wiring is secure and intact.

  2. 2

    Verify the parameterization for temperature monitoring (p0600, p0601) to ensure it is correct for the installed sensor type.

  3. 3

    For induction motors, if temperature sensor monitoring is not critical or is handled externally, consider de-activating the temperature sensor fault by setting p0607 to 0.