Control Power Supply Voltage Fault
Yaskawa · J1000 AC Drive
What does Uv2 mean?
The voltage supplied to the control drive input power is too low. This can occur if parameter L2-02 is changed from its default value without installing a Momentary Power Loss Ride-Thru unit, or if there is damage to the control power supply wiring or internal control circuitry, impacting drive control stability.
Complete Troubleshooting Guide
- 1
For specific drive models (CIMR-A*2A0004-2A0056 and CIMR-A*4A0002-4A0031), correct parameter L2-02 setting or install an optional Momentary Power Loss Ride-Thru unit.
- 2
Cycle power to the drive. If the fault reoccurs, inspect and replace any damaged control power supply wiring, the control board, or the entire drive.
- 3
If internal circuitry damage is suspected, cycle power again. If the problem continues, replace either the control board or the entire drive; contact Yaskawa for assistance.