EF7

External Fault (Terminal S7)

Yaskawa · V1000 AC Drive

What does EF7 mean?

This fault indicates that an external device triggered a fault via the Multi-Function Digital Input (MFDI) terminal S7, or there is incorrect wiring to S7, or the terminal is incorrectly configured for an external fault despite not being in use. This causes the drive to halt operation based on an external signal, potentially stopping connected machinery.

Complete Troubleshooting Guide

  1. 1

    Identify the external device connected to MFDI terminal S7 and resolve the cause of its fault condition.

  2. 2

    Verify and correctly connect the signal line to MFDI terminal S7.

  3. 3

    Ensure the MFDI settings for terminal S7 (parameter H1-07) are correctly configured for its intended use, or adjust if the terminal is not in use.