E2054

Not homed

Bosch Rexroth · IndraDrive C Drive Controllers

What does E2054 mean?

The axis has not been referenced or 'homed' since power-up or a previous reset. This prevents accurate absolute positioning and certain motion commands.

Common Causes

  • Homing procedure has not been performed after drive power-on or reset.
  • Homing switch or sensor malfunction preventing successful homing.
  • Loss of encoder absolute position reference (e.g., due to battery loss for multi-turn encoders).
  • Incorrect homing parameters or sequence configured in the drive controller.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Initiate the homing procedure for the axis according to the machine's operational manual.

  2. 2

    Verify the functionality of the homing switch or sensor and its wiring to the drive's inputs.

  3. 3

    Check the battery status for absolute encoders, if applicable, and replace if low or depleted.

  4. 4

    Review homing parameters (e.g., homing offset, homing speed, homing direction) in the drive configuration and ensure they are correct for the application.

Browse all codes in this manual (66)
Verified technical data. Last updated: March 2026