F2892

Hardware variant not supported

Bosch Rexroth · IndraDrive MPx02

What does F2892 mean?

The detected hardware variant of the drive or an installed module is not supported by the current firmware. This typically occurs when a new or different hardware version is used with an older or incompatible firmware release. The drive will not be able to operate safely or correctly without compatible firmware.

Common Causes

  • Firmware version is too old for the installed hardware
  • Hardware is not officially supported by the drive system
  • Incorrect hardware module installed (e.g., wrong revision)
  • Mismatch between control and power section hardware versions
  • Corrupted firmware preventing proper hardware recognition

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Verify the exact part numbers and revision levels of the IndraDrive MPx02 and all installed option modules by physically inspecting their labels.

  2. 2

    Check the currently installed firmware version of the IndraDrive MPx02 via the drive's display or using Bosch Rexroth IndraWorks diagnostic software.

  3. 3

    Consult Bosch Rexroth documentation (e.g., firmware release notes, compatibility lists) to determine the compatible firmware version for the detected hardware variant(s).

  4. 4

    Review the system's maintenance logs or installation records to identify any recent hardware replacements or upgrades of the drive or its modules.

Browse all codes in this manual (60)
Verified technical data. Last updated: March 2026

Related Faults

Source: Bosch Rexroth IndraDrive MPx02