Error when unlocking the safety door
Bosch Rexroth · IndraDrive MPx02
What does F3145 mean?
An error occurred during the process of unlocking a safety door. Safety doors are typically interlocked and require a specific sequence or condition to unlock safely. This fault indicates a malfunction in the door interlock mechanism, its sensor, or the control logic, preventing the door from opening or confirming its open status, potentially trapping personnel.
Common Causes
- Defective safety door lock mechanism or solenoid
- Faulty safety door switch or sensor
- Wiring damage to the safety door interlock circuit
- Incorrect control logic for door unlocking sequence
- Mechanical obstruction preventing the door from unlocking
Repair Steps & Checklist
Click steps to track your progress.
- 1
Verify the physical state of the safety door, interlock mechanism, and associated hardware for any obstructions, damage, or misalignment.
- 2
Inspect the wiring and connections for the safety door interlock sensor and actuator, checking for loose terminals, cut wires, or corrosion.
- 3
Measure the supply voltage at the safety door interlock sensor and actuator to ensure it is within the specified operating range.
- 4
Check the digital input status of the safety door interlock signals within the IndraDrive MPx02 diagnostic interface to confirm correct signal reception.
- 5
Verify the safety function parameters in the IndraDrive MPx02 configuration related to the safety door interlock (e.g., enable, timeout, logic).