F2123

Retain data backup impossible

Bosch Rexroth · IndraDrive MPx02

What does F2123 mean?

The drive was unable to perform or complete a backup of its retain data. Retain data typically includes critical parameters and settings that need to persist across power cycles. Failure to back up this data could lead to loss of configuration upon restart or prevent safe operation.

Common Causes

  • Defective non-volatile memory for retain data storage
  • Insufficient memory space for backup
  • Internal communication error during data transfer
  • Software fault preventing backup operation
  • Power supply instability during backup attempt

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Cycle power to the IndraDrive MPx02 and observe if the F2123 error persists.

  2. 2

    Verify the main power supply voltage to the IndraDrive MPx02 at the input terminals for stability and correct nominal value.

  3. 3

    Inspect the IndraDrive's diagnostic buffer and fault history for any additional, co-occurring error codes or warnings.

  4. 4

    Verify the specific configuration parameters governing retain data backup and storage paths within the IndraDrive settings.

  5. 5

    Inspect any inserted memory card (e.g., SD card) for proper seating, physical damage, and available storage capacity, as this is often used for configuration and retain data.

Browse all codes in this manual (60)
Verified technical data. Last updated: March 2026

Related Faults

Source: Bosch Rexroth IndraDrive MPx02