CCD communication error
Bosch Rexroth · IndraDrive MPx02
What does F4140 mean?
This fault signifies a communication error within the CCD (C-channel Communication Driver) system, which is part of the internal communication architecture of the IndraDrive MPx02. This error can affect internal data exchange necessary for drive operation.
Common Causes
- Internal communication disruption within the IndraDrive MPx02 control section.
- Faulty control section or hardware component related to the CCD.
- Firmware incompatibility or corruption on the IndraDrive MPx02.
- Significant electromagnetic interference affecting internal data buses.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Perform a power cycle of the IndraDrive MPx02 to clear any transient communication issues.
- 2
Verify that the IndraDrive MPx02 firmware is up to date and compatible with the installed hardware options.
- 3
Inspect the control section and power section connections for secure seating, especially if modules are interchangeable.
- 4
Check the system for sources of strong electromagnetic interference that could affect internal communication.
- 5
If the fault persists, consider contacting Bosch Rexroth support as this may indicate an internal hardware defect in the control unit.