F7013

Velocity threshold exceeded

Bosch Rexroth · IndraDrive MPx02

What does F7013 mean?

This safety technology error indicates that the actual velocity of the motor has exceeded a safety-related velocity threshold configured in the IndraDrive MPx02. This is a critical safety violation, implying the motor is moving too fast for the current safety-monitored state, leading to an immediate safety stop.

Common Causes

  • Incorrectly parameterized safety-related velocity threshold (e.g., S-0-0100 'Safe maximum velocity') for the current operating mode.
  • Loss of speed control due to incorrect tuning or external disturbances.
  • Encoder fault or noise leading to erroneous velocity feedback.
  • Commanded velocity exceeding the safe limit for the selected operating conditions.
  • External mechanical forces causing an uncontrolled acceleration.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Review and adjust the safety-related velocity threshold parameters (e.g., S-0-0100) in the IndraDrive MPx02, ensuring they are appropriate for the application's safety requirements.

  2. 2

    Check the tuning of the velocity control loop to ensure stable and accurate speed regulation.

  3. 3

    Verify the motor encoder for accurate and consistent velocity feedback. Inspect wiring for damage or noise.

  4. 4

    Analyze the commanded motion profile and machine operation to ensure that the motor's speed never exceeds the set safe velocity threshold.

  5. 5

    Inspect the mechanical system for any binding, excessive play, or external forces that could cause unintended acceleration.

Browse all codes in this manual (99)
Verified technical data. Last updated: March 2026

Related Faults

Source: Bosch Rexroth IndraDrive MPx02