Safety related end position exceeded
Bosch Rexroth · IndraDrive MPx02
What does F7021 mean?
This safety technology error indicates that the motor's actual position has exceeded a defined safety-related end position limit on the IndraDrive MPx02. This is a critical safety violation, meaning the axis has moved beyond its designated safe travel range, necessitating an immediate safety stop.
Common Causes
- Incorrectly set safety-related end position limits (e.g., S-0-0193, S-0-0194) in the IndraDrive MPx02.
- Encoder counting error, offset, or corruption, leading to incorrect actual position reporting.
- Loss of control or an unexpected motion command pushing the axis beyond its limits.
- Mechanical overrun due to inertia, brake failure, or external forces.
- Faulty or misaligned external safety limit switch or sensor.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Review and adjust the safety-related end position limit parameters (e.g., S-0-0193 'Positive limit', S-0-0194 'Negative limit') in the IndraDrive MPx02, ensuring they align with the machine's physical limits.
- 2
Verify the motor encoder for accurate position feedback. Check for mechanical slippage, loose couplings, or encoder damage.
- 3
Inspect any external safety limit switches or sensors and their wiring for proper function and connection.
- 4
Analyze the commanded motion profile to ensure that no trajectory attempts to exceed these safety end positions.
- 5
Perform a re-referencing or recalibration of the axis position, if applicable, to ensure accurate absolute positioning.