715

Internal fault (e.g. residual current monitoring unit)

Fronius · Primo GEN24

Was bedeutet 715 ?

The Fronius Primo GEN24 208-240 inverter has detected an internal fault within its residual current monitoring unit (RCMU). This unit is crucial for detecting ground faults and ensuring safety. A fault here means the inverter cannot safely operate and will shut down.

Häufige Ursachen

  • Internal fault (e.g. residual current monitoring unit).

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Perform a full power cycle of the Fronius Primo GEN24 208-240 inverter by opening both the AC circuit breaker and the DC disconnector, waiting, and then reclosing them.

  2. 2

    Ensure there are no actual ground faults in either the AC or DC circuits that might be causing the RCMU to incorrectly trip or fail.

  3. 3

    Check for any moisture ingress or contamination within the inverter that could affect sensitive RCMU components.

  4. 4

    Review the inverter's event log for any preceding fault codes related to insulation faults (e.g., 3xx codes) or grid issues.

  5. 5

    As this is a critical safety component, if the fault persists, contact Fronius service immediately for inspection and potential replacement of the RCMU.