Übersetzen...
231-A043

CC%2 SOM 2 only one axis allowed

Heidenhain · TNC CNC Controllers

Was bedeutet 231-A043 ?

This error indicates that in operating mode BA2, with open safety doors, the simultaneous movement of more than one axis is not allowed. The controller has detected an attempt to move multiple axes under these restricted conditions.

Häufige Ursachen

  • Simultaneous movement of more than one axis attempted in operating mode BA2 with open safety doors.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Ensure all axes are at a complete standstill before attempting to move any single axis in operating mode BA2 with open safety doors.

  2. 2

    Only initiate movement for one axis at a time in operating mode BA2 when safety doors are open.

  3. 3

    Close the safety doors if simultaneous multi-axis movement is required.

  4. 4

    Review the machine's safety manual for specific restrictions and procedures in operating mode BA2.

Alle Codes in diesem Handbuch durchsuchen (47)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes

Heidenhain 231-A043 Support: CC%2 SOM 2 only one axis allow… | ErrorLib