Übersetzen...
231-A081

CC%2 cross comparison failed

Heidenhain · TNC CNC Controllers

Was bedeutet 231-A081 ?

This error signifies a discrepancy in input or output data of the safety core software during a cross-comparison between the MC (Machine Control) and CC (Controller). This can affect various safety-related functions, including axis group states, motion requests, axis movement releases, machine control voltage, drive enable permissions, machine key statuses, brake-line test signals, safety-related mode of operation (SOM), read-back outputs, SPLC program activity, and stop requests. It also indicates issues with ascertained safety status of the axis group, axis-dependent braking control, motion status, or operating readiness for functional safety.

Häufige Ursachen

  • Difference found in input data of the safety core software during cross-comparison between MC and CC (e.g., pp_AxGrpStateReq, pp_AxGrpActivate, pp_AxFeedEnable, pp_GenCVO, pp_AxGrpPermitDrvOn, pp_GenMKG, pp_GenTBRK, pp_GenSOM, readBackOutputs, running, stopReq).
  • Difference found in output data of the safety core software during cross-comparison between MC and CC (e.g., NN_AxGrpState, NN_AxBrkReleaseReq, NN_AxGrpInMotion, NN_GenSafe).
  • Error in the Safety PLC (SPLC) program causing inconsistent data between MC and CC.
  • Communication errors or delays between MC and CC leading to out-of-sync data.
  • Incorrect or corrupted safety-related configuration or parameters.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Review and meticulously check the Safety PLC (SPLC) program for logical errors, inconsistencies, or timing issues that could lead to data mismatches.

  2. 2

    Verify that all safety-related input signals (e.g., pp_GenCVO, pp_GenMKG, pp_GenTBRK, pp_GenSOM) are stable and correctly transmitted between MC and CC.

  3. 3

    Inspect communication cables and connections between the MC and CC units for damage, loose contacts, or electromagnetic interference.

  4. 4

    Ensure that all parameters related to axis groups, drive enables, and operating modes are correctly configured and consistent across the system.

  5. 5

    If the issue persists, consider reloading the SPLC program and safety configuration, or updating software versions to address potential bugs or incompatibilities.

Alle Codes in diesem Handbuch durchsuchen (47)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes