Übersetzen...
231-A086

SKERN-CC%2: Communications error during dynamic sampling of X%4

Heidenhain · TNC CNC Controllers

Was bedeutet 231-A086 ?

This error indicates that the dynamic sampling of the EnDat22 encoder (X%4) could not be performed within the prescribed time limit. This is a communication timeout issue, suggesting problems with the encoder, its wiring, or the controller's ability to communicate with it.

Häufige Ursachen

  • The dynamic sampling of the EnDat22 encoder (X%4) could not be performed within the prescribed time.
  • Faulty EnDat22 encoder or damaged encoder cable.
  • Timing issues or heavy load on the controller preventing timely communication.
  • Electrical interference affecting the EnDat communication.
  • Incorrectly configured encoder parameters or communication settings.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Inspect the EnDat22 encoder cable (X%4) for any physical damage, proper shielding, and secure connections.

  2. 2

    Verify the integrity and power supply to the EnDat22 encoder itself.

  3. 3

    Check the controller's diagnostic logs for other concurrent errors that might indicate an overloaded system or internal communication issues.

  4. 4

    Ensure all communication parameters for the EnDat22 encoder are correctly configured according to the manual.

  5. 5

    Test the encoder and its cable separately if possible, or swap components with a known good one if available.

Alle Codes in diesem Handbuch durchsuchen (47)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes