Übersetzen...
06

Phase failure

SEW Eurodrive · [PDF] Operating Instructions

Was bedeutet 06 ?

The drive has detected a missing phase in the supply system leads. This fault is typically only detectable when the drive is operating under load, indicating an imbalance or complete loss of one or more input phases. Continued operation with a phase failure can lead to damage in both the motor and the inverter.

Häufige Ursachen

  • One or more phases are missing in the supply system lead.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Check the supply system lead for phase failure by measuring phase-to-phase voltages at the inverter input using a multimeter.

  2. 2

    Reset the fault by switching off the DC 24 V supply voltage to the inverter for at least 10 seconds.

Alle Codes in diesem Handbuch durchsuchen (11)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes