ABB · ACS580
The control panel or PC tool, configured as the active control location, has ceased communication with the drive. This results in a loss of local control and monitoring capabilities, potentially stopping the drive or preventing startup.
Click steps to track your progress.
Verify the control panel cable is securely connected to both the panel and the drive's designated port.
Test the control panel on another known good drive, or swap it with a spare panel to isolate the issue to the panel itself.
Measure the voltage at the drive's control panel port (e.g., 24VDC between specific pins) to confirm power supply.
If using a PC tool, restart the PC, re-establish the USB or Ethernet connection, and verify network settings (e.g., IP address on P7-08).
If the fault is intermittent, check for EMI interference by ensuring proper cable shielding and grounding for the control panel cable.