Allen-Bradley · PowerFlex 750
The DC bus voltage on port 1 has dipped more than 180V below the drive's bus memory when the drive is offline or in stand-alone mode. This indicates an unstable DC bus voltage, which can affect drive reliability.
Click steps to track your progress.
Use a power quality analyzer to monitor the 3-phase AC input voltage (Port 1) for sags or momentary interruptions.
Inspect and tighten all input power wiring connections at the drive's L1, L2, L3 terminals (Port 1) and upstream devices.
Inspect DC link capacitors (Port 1) for physical defects like bulging, leaking electrolyte, or discoloration.
Verify the integrity and correct connection of any external braking resistors or regenerative units associated with Port 1.
Measure the actual DC bus voltage across the P+ and N- terminals (Port 1) with a multimeter to verify the controller's displayed value.