112

PwrBd App MinVer

Allen-Bradley · PowerFlex 750

What does 112 mean?

This fault indicates that the power structure requires a newer Application revision to be compatible with the main control board. The firmware on the power structure is outdated or incompatible, preventing correct drive operation. The drive will not function until the power board firmware is updated to the required version.

Common Causes

  • Main control board (MCB) has a newer firmware version that requires a minimum application revision on the power board (PB).
  • The power board's application firmware is outdated, corrupted, or incompatible with the MCB's current firmware.
  • Installation of an older generation power board with a newer generation main control board.
  • Firmware update procedure for the power board was incomplete or failed.
  • Internal communication issues preventing the MCB from correctly reading the PB's application version.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    1. Identify the current firmware versions of both the main control board (MCB) and the power board (PB) using programming software (e.g., DriveTools SP).

  2. 2

    2. Obtain the correct, compatible firmware update file for the power board based on its model and the MCB's version.

  3. 3

    3. Perform a firmware update on the power board (PB) using the approved flashing tool and procedure, ensuring no interruptions.

  4. 4

    4. Verify that the MCB and PB are from compatible product series and generations as specified in the drive's documentation.

  5. 5

    5. If the firmware update fails or the fault persists, replace the power board (PB).

Browse all codes in this manual (60)
Verified technical data. Last updated: April 2026

Related Faults

100Parameter Chksum101PwrDn NVS Blank10132I1 Incompat PS
Source: Allen-Bradley PowerFlex 750
View Official PDFSearch more codes in this manual