Beckhoff · TwinCAT 2 NC
An unacceptable value (outside the range of 1 to 255) has been used for an axis identifier, or the specified axis does not exist within the current system configuration. This parameter error prevents proper identification and control of the specified axis, leading to its inability to move or respond to commands.
Click steps to track your progress.
1. Review the NC program or PLC command that generated the error and adjust the axis identifier to a valid, configured axis (e.g., Axis 1, Axis 2).
2. Check the NC configuration parameter P4-01 ('Number of Axes') to ensure it matches the physical and logical axis count.
3. Verify the axis definitions in the NC setup (e.g., System Configuration menu > Axes) to confirm the specified axis exists and is enabled.
4. Reload the NC configuration from a backup file to ensure proper axis definitions.
5. Debug any external systems (e.g., HMI, SCADA) that send axis commands to ensure they use valid axis identifiers.