Beckhoff · TwinCAT 2 NC
This error signifies that an invalid controller type has been configured or detected for an encoder. The system expects a specific type of controller for the connected encoder but found a mismatch or an undefined type. This mismatch prevents the NC from applying the correct control algorithms and parameters, rendering the encoder unusable.
Click steps to track your progress.
1. Access the encoder controller type parameter (e.g., P1-04) in the drive configuration and set it to match the actual encoder and controller specifications (e.g., 1 for incremental, 2 for absolute).
2. Consult the encoder's datasheet and the drive's manual to confirm the correct numerical value for the encoder controller type.
3. Check for any available firmware updates for the drive that might introduce support for the intended encoder controller type.
4. Perform a parameter upload from the drive and then a download of the corrected parameter set to ensure data integrity.
5. Visually inspect the encoder and verify its model number to definitively determine its actual type (e.g., incremental, absolute, resolver).